1. Home
  2. Products
  3. nPLANE™ RAS Nasal Molding System
  4. nPLANE™ Nasal Molding Clinic Kit
nPlane RAS Device
nPlane RAS Device

nPLANE™ Nasal Molding Clinic Kit

Part Number: CR5750
Availability: In Stock
You must be registered to order this product.
The nPLANE clinic kits include multiple conformers for more flexible distribution to patients.  The clinic kits include all sizes of the conformers, and can be used to treat approximately 15, 30 or 45 patients depending on the kit size. 

The nPLANE clinic kits come in 3 sizes:

Kit ID
Patient Kit (Approximately)
Total Conformers
Includes
Average cost per patient
CR7501515 Patients
50
5x size 01; 15x size 02; 3x sizes 03, 04, 4x sizes 03R, 04R, 8x sizes 03L, 04L$482
CR75030 30 Patients
100
10x size 01; 30x size 02; 6x sizes 03, 04, 8x sizes 03R, 04R, 16x sizes 03L, 04L$425
CR75045 45 Patients
150
15x size 01; 45x size 02; 9x sizes 03, 04, 12x sizes 03R, 04R, 24x sizes 03L, 04L$375

The kits include sizes based on the average distribution of clefts between unilateral left and right, and bilateral cases. Additionally, size 01 is only used in very small babies and not used in all cases.
The kits can be refilled with the 5, 10 or 15 Conformer Clinic Refill Packs

It specifically addresses the vertical and transverse asymmetries of the nose, displacing the septum and nostrils to a more physiological and aesthetic position before surgery and maintains the correction of the nasal cartilage, to avoid its collapse after surgery.  Watch our video to learn more about usage here. 

Each patient may used the nPLANE™ conformers from small to large in sizes 1 to 4.  The patient will progress up in size as they grow, and larger patients may not need the size 01.  In all kits, the smaller size 01 and size 02 conformers have symmetrical shaped nostril portions.  In sizes 03 and 04, the unilateral conformers have one nostril section larger on either the left or right side.  The bilateral conformers have symmetrical nostril sections in all sizes 01 through 04.

The nPLANE™ RAS Rhinoplasty Appliance System was designed by Dr. Martha Mejia to correct the patient’s caudal nasal septal deviation, improve the nostril circumference and columellar length, elevate the nasal tip, and approximate the soft and hard tissue borders of the cleft defect.

Product Info:
CR575015 - nPLANE™ Clinic Kit 15 - Devices for approximately 15 patients. 
CR575030 - nPLANE™ Clinic Kit 30 - Devices for approximately 30 patients. 
CR575045 - nPLANE™ Clinic Kit 45 - Devices for approximately 45 patients. 


Patent US20070219575A1

Related Items

TOP Logo